A310 EMERGENCY CHECKLIST IN FLIGHT ENGINE FIRE Throttle ............................. IDLE Fuel Lever ............................ OFF Fire Handle .......................... PULL First Agent After 10 Seconds .... DISCHARGE • If fire after further 30 seconds, Second Agent ................. DISCHARGE Land as soon as possible. Use Single Engine Operation procedure on Abnormal Checklist page (T). ON GROUND ENGINE FIRE Throttle ................. • When airplane stopped, Parking Brake.......... Fuel Lever.............. Fire Handle ............ First Agent ........... ..... IDLE .....SET ..... OFF ..... PULL DISCHARGE • If fire after further 30 seconds, Second Agent.................. DISCHARGE • If evacuation required, Ram Air ................................ON Fuel Levers ...........................OFF Fire Handles (engine and APU).........PULL Fuel Isolation Valves..........OFF Agent Discharge (engine and APU) .. .declare Notify passengers to leave the airplane. Notify tower on VHF 1. Perform evacuation assignments. EMERGENCY DESCENT Transponder Code ......................... 7700 Notify ATC...........GET ALTIMETER SETTING MEA or 14,000 Ft ........................ LEVEL Flight Attendants and Passengers.......ADVISE Descend to 10,000 ft cabin altitude as soon as possible at a cabin rate of 300-400 fpm. Oxygen Masks . . .. ON Ignition . . . CONTINUOUS RELIGHT Throttles DISCONNECT & IDLE Speedbrake FULL Maximum Speed .................. VMO • If cabin altitude above 14,000 ft, Passenger Oxygen............ GREEN LIGHT PA Announcement ... USE OXYGEN MASKS SMOKE SOURCE IDENTIFICATION Land at nearest suitable airport. Consider use of oxygen masks and goggles. • If a smoke lightis on, use applicable Smoke checklist, page (5). • If a smoke light is not on, check the following in order: AIRCONDITIONING Cockpit Airconditioning Outlets .... CHECK FOR SMOKE OR ODOR • If smoke or odor is present, use Airconditioning Smoke checklist page (5). PASSENGER CABIN No Smoking, Seat Belts....................ON Contact Purser........CHECK LAVS, GALLEYS, & CABIN • If galley smoke or fire, keep oven door closed except to fight fire. Set galley switchlight to shed. • If cabin light smoke, turn cabin lights off at cabin lighting panel. • If lavatory smoke, close door except to fight fire. Pull associated lavatory CBs on panel in cabin ceiling adjacent to lavatories. • If smoke stops, use normal ventilation to evacuate residual smoke. APU FIRE Fire Handle Agent After 10 Seconds Master Switch PULL DISCHARGE OFF • If fire warning persists, Land as soon as possible. RUNAWAY TRIM Trim Wheel HOLD Pitch Trim Switches CHECK OFF Use manual trim or the good electric trim system if it can be identified. FAA Approved Sep 10, 1986 315.010 p 1
Object Description
Description
Title | Page 1 |
Object ID | asm0341006943 |
Digital ID | asm03410069430001001 |
Full Text | A310 EMERGENCY CHECKLIST IN FLIGHT ENGINE FIRE Throttle ............................. IDLE Fuel Lever ............................ OFF Fire Handle .......................... PULL First Agent After 10 Seconds .... DISCHARGE • If fire after further 30 seconds, Second Agent ................. DISCHARGE Land as soon as possible. Use Single Engine Operation procedure on Abnormal Checklist page (T). ON GROUND ENGINE FIRE Throttle ................. • When airplane stopped, Parking Brake.......... Fuel Lever.............. Fire Handle ............ First Agent ........... ..... IDLE .....SET ..... OFF ..... PULL DISCHARGE • If fire after further 30 seconds, Second Agent.................. DISCHARGE • If evacuation required, Ram Air ................................ON Fuel Levers ...........................OFF Fire Handles (engine and APU).........PULL Fuel Isolation Valves..........OFF Agent Discharge (engine and APU) .. .declare Notify passengers to leave the airplane. Notify tower on VHF 1. Perform evacuation assignments. EMERGENCY DESCENT Transponder Code ......................... 7700 Notify ATC...........GET ALTIMETER SETTING MEA or 14,000 Ft ........................ LEVEL Flight Attendants and Passengers.......ADVISE Descend to 10,000 ft cabin altitude as soon as possible at a cabin rate of 300-400 fpm. Oxygen Masks . . .. ON Ignition . . . CONTINUOUS RELIGHT Throttles DISCONNECT & IDLE Speedbrake FULL Maximum Speed .................. VMO • If cabin altitude above 14,000 ft, Passenger Oxygen............ GREEN LIGHT PA Announcement ... USE OXYGEN MASKS SMOKE SOURCE IDENTIFICATION Land at nearest suitable airport. Consider use of oxygen masks and goggles. • If a smoke lightis on, use applicable Smoke checklist, page (5). • If a smoke light is not on, check the following in order: AIRCONDITIONING Cockpit Airconditioning Outlets .... CHECK FOR SMOKE OR ODOR • If smoke or odor is present, use Airconditioning Smoke checklist page (5). PASSENGER CABIN No Smoking, Seat Belts....................ON Contact Purser........CHECK LAVS, GALLEYS, & CABIN • If galley smoke or fire, keep oven door closed except to fight fire. Set galley switchlight to shed. • If cabin light smoke, turn cabin lights off at cabin lighting panel. • If lavatory smoke, close door except to fight fire. Pull associated lavatory CBs on panel in cabin ceiling adjacent to lavatories. • If smoke stops, use normal ventilation to evacuate residual smoke. APU FIRE Fire Handle Agent After 10 Seconds Master Switch PULL DISCHARGE OFF • If fire warning persists, Land as soon as possible. RUNAWAY TRIM Trim Wheel HOLD Pitch Trim Switches CHECK OFF Use manual trim or the good electric trim system if it can be identified. FAA Approved Sep 10, 1986 315.010 p 1 |
Archive | asm03410069430001001.tif |
Tags
Comments
Post a Comment for Page 1